Hi, I've been trying to use the number display on NB designer HMI. it is connected to an NX1 Controller with sysmac studio as the automation software. I have a timer on my program and i want to display it to my hmi screen. However, the screen of tge number display keeps on blinking with "****" and random numbers and not showing the elapsed time of my timer in plc. Thanks in advance!
NB DESIGNER NUMBER INPUT
connection to omron CJ1M PLC
I have an omron PLC (CJ1M type) at home which I would like to connect to, however, lately, I can't anymore. I'm trying on two different PC's a newer and an older one, both running on windows 10.
1 is just mentioning a DLL error and I can't even start cx-programmer, the other one seems to work, however, when I try to go online it always fails
I'm using a usb to serial device and after some searching on the net, I thought the issue was with the prolific driver. I tried all kind of fixes, but nothing seemed to work.
I have now purchased another device, the XS8801 from usconverters and installed the latest driver. I have checked if cx programmer is set to work with the correct port and this is the case.
My knowledge is very limited but I would really want to connect to that PLC again, so hoping someone out here is able to help me.
Thanks a lot
Omron NJ501 - IFM IO-Link - Wenglor U1KT001
Hi,
I am looking at reading an ultrasonic sensor value through IO-Link, using a Omron NJ501-1320 PLC connected through EtherCat to a IFM AL1332 master with a Wenglor U1KT001 Ultrasonic sensor.
I have managed to read the 2 outputs of the sensor using this:
Output_1 := TestABit(USINT_TO_BYTE(TxPDO_input_byte_1_6000_02),USINT#0);
Output_2 := TestABit(USINT_TO_BYTE(TxPDO_input_byte_1_6000_02),USINT#1);
But cannot read the ultrasonic sensor distance value, this is what page 2 in the manual says:
Measured Value in 1/10 mm 2…15 14 Bit 300…4500
Octet 1 Subindex 3 (LSB) 2 1 Bit Offset 7 6 5 4 3 2 1 0
I tried a couple of conversions but couldn`t get the distance reading.
Any ideas?
Help appreciated.
C200HE Backup
Does anyone know what the latest version of CS Programmer that includes the PLC Backup Tool that will support the C200HE-CPU42 PLC? I've gone back a couple of versions but they don't appear to support the C200
Plants with many PLCs OMRON
Hi colleagues,
I would like to ask you about companies in whose plants have many OMRON PLCs, such as NISSAN.
Thanks
OMRON PLC with Modbus TCP/IP
Hello
Has anyone got an Omron PLC running with Modbus TCP/IP?
If so was it difficult?
I'm thinking of using this PLC as it has Ethernet/IP as well.
http://www.ia.omron.com/products/family/3650/
Thanks!
CQM1H-CPU61 password recovery / Plc Backup Tools V6.0
Dear PLC forum.
I have an issue with a customer who has bought some equipment with CQM1H-CPU61 installed.
In order to program certain changes the device requires the password. Both I and the customer have contacted Omron but the only solution from their side was to buy a new system.
As I have managed to find via googling the password can be recovered with Plc Backup Tools V6.0 software.
Does anyone have the installer for this software and are they willing to share it with me?
Thanks in advance.
[NB-Designer] HMI "PLC No Response" error [SOLVED]
Hello everybody,
I continued my project this morning and my HMI gives the 'PLC No response 00-02-3" error... I haven't changed anything since last Friday, so in theory it should work. I used this tutorial a few weeks ago and that worked. I also tried so use some old programs which used to work, but they don't work now...
HMI IP: 192.168.250.1 (the addresses from the tutorial)
PLC IP: 192.168.250.2 (the addresses from the tutorial)
Does anyone know what could be the problem? I already tried using another switch, but that didn't work either.
EDIT: I just saw that I posted this in the wrong subforum, excuse me
EDIT2: I found the solution. I cleared the data memory before... So what I did was transfering the settings to the PLC, then completely power off the PLC and then power it on again. That worked for me!
Thanks,
Olivier
Memory Error
Hi All,
i have a problem with CQM1H , The ERR/ALM Lamp is ON and Error log shows a (Memory Error)
what can i do ? is it a hardware error?
i'm intending to format the memory but the installed program is full of errors while compiling so, i'm afraid not to be able to transfer the program to CPU
any of you faced that problem ??
thanks in advance
Sysmac Mini SK-20 cable wanted!
CP1E host link communication via serial port gives IC error code for Timer SV Read
Hi,
I'm trying to communicate Omron CP1E unit with PC via serial port using hostlink protocol. I need to read the Timer/Counter SV value and write the timer/counter SV values to the PLC. I'm able to use other C mode commands (like RC (timer/counter PV read), WC (timer/counter PV write) etc.) but when I give the command for Timer/Counter SV Read 1 which is R#, I get the response as IC (Undefined Command). How do I write or read the timer SV Values?
Example command and response :
@00R#TIMH001028* (TIMH is the high speed timer, 0010 is the timer number and 28 is the FCS)
Response:
@00IC4A*
Is is that CP1E doesn't support these commands? If so what is the equivalent command that I should send inorder to perform this?
Please help.
R88A-MCW151-DRT-E Motion controller
Connection with a CPM2A PLC
NT11S omrom panel
NX 120 volt digital inputs
We would like to use the NX102 for it's OPC UA capability but they don't appear to offer a 120 volt digital input card. The only seem to have a 220 volt input card.
We could use the NJ501 w/ CJ1W-IA111 cards but this processor is a little cost prohibitive compared to the NX102.
I was thinking about using their 32 point 24v input card (NX-ID6142-5) with interposing relays.
Has anyone found any good solutions for incorporating 120 volt digital inputs with the NX IO system?
NB HMI and CP1L-E PLC RTC Setup
Hello,
How to SET the RTC of the CP1L-EM40 PLC Using NB7Q-TW01 HMI.
Is it any way to transfer the data of LW10000 to LW10005 (Which is RTC of HMI) to the Auxiliary area of PLC which stores the RTC of PLC ?
CPU Selection
Hi All,
i have a project containig 3 servo drives what is the suitable and sheapist CPU to safsfy that needs
thanks in advance
cpu cpm1a
please help me to unlock the password of plc cpu cpm1a
Help me out to understand Graphic Designing in Omron NB HMI.
Hello there,
I am using Schneider HMI for the past few years, it's very versatile and easy to design graphics.
Now i started using OMRON HMIs and found that is weird to draw graphics in Omron NB-Designer.
I have Example, Look at the attached screenshot of both software, in the case of Schneider if I stretch a button or any object it will remain in the same good shape.
but in the case of Omron, if you stretch any object it doesn't remain in the original shape. (check the attached images.)
Please suggest Ideas about designing a good Omron Hmi, Sample backup is always welcome.
The image link is below, I am not able to upload it here.
Omron FQ2 Ethernet/IP comunication with Allen Bradley PLC
Hello guys.
I have problem create communication between Omron FQ2 camera and Allen Bradley PLC. Can anyone advise me ? I set it up according to this manual: ftp://85.129.89.106/Vision/FQ/Communication/EthernetIP/FQ2%20to%20AB.pdf.